It is a common practice among HVAC companies to put several unique
features into their gas furnaces,
which make them, stand out from the rest. Goodman does something similar with
their GMVC8. Moreover, due to their diligence and attention to detail, they
have managed to produce a gas furnace perfect for the 4-ton two-stage system.
Some of the most notable features include:
-
The heavy-duty aluminized-steel tubular heat
exchanger
-
Two-stage gas valve
-
Self-diagnostic control board
-
Corrosion-resistant vent variable-speed blower
-
Durable silicon nitride igniter
-
Insulated furnace cabinet
The heavy-duty heat exchanger is well designed for efficient performance
even when under load and provides superior heat transfer. On top of this, you
have the two-stage gas valve, which uses a lower operation mode to keep your
energy consumption low when the demand for heating is low. This serves as an effective
measure in increasing the efficiency of your system.
In terms of durability, Goodman has taken several innovative steps
to ensure your system stays operational at high efficiency for extended
periods. Unlike many other Gas Furnaces available on the market, Goodman has
equipped their gas furnace with a self-diagnostic control board, which strictly
monitors the interior functions of the gas furnace and ensures that everything
is in order. Furthermore, it allows air conditioning repair experts to quickly
identify problems and carry on thoroughly with ac maintenance & repair.
Finally, to protect all the internals of the gas furnace, you are
given an insulated furnace cabinet, which adds to the energy efficiency of the
gas furnace. Goodman achieves this by completely insulating the cabinet and
trapping almost all of the heat inside, with a low air leakage rate of only 2%.
Furthermore, the insulated cabinet also functions as a noise suppressant and
keeps the noise levels of the gas furnace even when under load, significantly
low.
Specifications: -
General Information
|
|
Type
|
Gas Furnace
|
Fuel Type
|
Natural Gas
|
Vent Type
|
Direct
Vent
|
Modulating/Staging
|
Two Stage
|
Blower motor
|
ECM Variable-speed
|
Configuration
|
Upflow/Horizontal
|
Gas Conversion Kit
|
Available
|
UPC
|
663051567405
|
Performance
|
|
Heating BTU
|
80000
|
High Fire Input
|
80000 BTU
|
Low Fire Input
|
56000 BTU
|
High Fire Output
|
64000 BTU
|
Low Fire Output
|
44800 BTU
|
AFUE
|
80%
|
Minimum Air flow
|
2000 CFM
|
Low NOx Emissions
|
No
|
Electrical Data
|
|
Voltage
|
115 Volts
|
Phase
|
1
|
Frequency
|
60 Hz
|
Minimum Circuit Ampacity
|
10.6 Amps
|
Recommended Breaker Size
|
15 Amps
|
Dimensions
|
|
Flue Connection
Size
|
4"
|
Cabinet Width
|
21"
|
Product Height
|
33 1/2”
|
Product Width
|
21”
|
Product Depth
|
28”
|
Shipping weight
|
121 lbs
|
Certifications
|
|
Country Of Origin
|
United States
|
ETL Listed
|
Yes
|
AHRI Certified
|
Yes
|
ISO Certified
|
Yes
|
AHRI
|
202327713
|
Warranty Information
|
|
Unit Replacement Warranty
|
10 Years
|
Parts Warranty
|
10 Years
|
Heat Exchanger Warranty
|
Lifetime
|